Fire & Safety

View Cart | Checkout | Items: , Value:

spacer

Company Information

spacer
spacer

Best Sellers

This door must be kept closed

This door must be kept closed

This door must be kept closed. Self adhesive vinyl 200 x 200mm.

find out more

£2.40

Keep locked shut

Keep locked shut

Keep locked shut. Self adhesive vinyl 100 x 100mm.

find out more

£0.72

Keep clear

Keep clear

Keep clear. Self adhesive vinyl 200 x 300mm.

find out more

£3.36

Thank you for not smoking.

Thank you for not smoking.

Thank you for not smoking. 1mm rigid plastic.

find out more

Strictly no admittance.

Strictly no admittance.

Strictly no admittance. 1mm rigid plastic.

find out more

spacer

Fike Twinflex Panels & Kits

Fire & Safety |  Fire Alarm Parts |  Fike Twinflex Panels & Kits

Fike 2 Zone Panel

Fike 2 Zone Panel

Ref: TFP2


Price: £340.03 (Including VAT at 20%)

Quantity:

Conventional Panel with 2 zones,
Using the Multipoint detector as part of the Twinflex 2-wire fire alarm system means that when a detector is wired in, a sounder is too - with no extra wiring. This greatly reduces the number of points that need to be installed and the time it takes to install them.

As the Multipoint offers 7 different modes of detection, the installation is made even simpler as this one device suits all applications. Whatever type of detection is required, for any part of the installation, it can be selected by the flick of a switch at the time of commissioning. Any one of the 3 different smoke modes, 2 fixed temperature heat modes, a rate of rise mode and a combination smoke or heat mode can be selected.


As the Multipoint detector is available with or without a full specification 92dBA sounder (for only a marginal cost difference) no extra devices need to be purchased when audible warning is required (meets audibilty levels recommended in BS5839 Part 1: 1988). Twinflex callpoints can be run on the same pair of wires as detectors. Further cost savings can be utilised by using the new combined callpoint / sounder. Both detectors and callpoints have a selectable EOL module so any device can be set as the end of line monitor. The panel can also differentiate between callpoint or detector alarms.


If extra sound is required, or for areas that do not require detection, then the Hatari Sounder can be used on the same two wires, offering sound output of 100dBA. It also has a built-in EOL monitoring switch.

The panel can accommodate 32 devices per zone, has separate fault monitoring displays for each zone, and a one man walk test facility. Zones are configured without the need to use resistors or capacitors on unused zones.


Two wire installation - only one circuit per zone to connect detectors and sounders.
Installation savings as high as 40% - save on cable, installation time and sounders.
Callpoint identification - panel can differentiate between callpoint or detector alarms.
Built-in end of line device - all devices including detectors, callpoints and stand-alone sounders have a selectable built-in end of line monitoring function. No resistors or extra circuits required.
No base diode requirement.
Multipoint detector provides 7 modes of detection.
System fully complies with BS and EN.
32 devices per zone.
Easy to install - no need to worry about marking "in's" and "out's".
Available with 2,4 and 8 zone panels.
8 and 16 zone repeater panels available.
72 hour standby.
Auxiliary sounder circuit.
Output module for plant switching, door release etc.

4 Zone Panel

4 Zone Panel

Ref: TFP4


Price: £480.00 (Including VAT at 20%)

Quantity:

Conventional Panel with 4 zones

Details as 2 zone panel above

8 Zone Panel Metal Box

8 Zone Panel Metal Box

Ref: TFP8


Price: £739.80 (Including VAT at 20%)

Quantity:

Conventional Panel with 8 zones

Details as 2 zone panel above

8 Zone Repeater Panel

8 Zone Repeater Panel

Ref: TRP8


Price: £180.00 (Including VAT at 20%)

Quantity:

Conventional Repeater with 8 zone indications, 6 cores & 1 core per zone powered from control panel

16 Zone Repeater Panel

16 Zone Repeater Panel

Ref: TRP16


Price: £219.96 (Including VAT at 20%)

Quantity:

Conventional Repeater with 16 zone indications, 6 cores & 1 core per zone powered from control panel

2 Zone Twinflex PLUS panel

2 Zone Twinflex PLUS panel

Ref: TP2


Price: £419.95 (Including VAT at 20%)

Quantity:

How It Works
At the planning stage, fire zones are designated as either "Dwelling" or "Communal". Multipoint detectors in the dwelling zones have the facility to use "checkpoint" technology - see Feature Article: "Checkpoint Technology Filters Nuisance Alarms on Conventional System"


"Checkpoint" technology is the ability to select a checking period for individual detectors to confirm the smoke/heat detected as a genuine fire not an unwanted alarm.

This checking period can be selected between 1 - 8 minutes at commissioning stage after consultation with fire officers or other authorised bodies.

FEATURES

Two wire installation plus all the features of the standard Twinflex system.
Programmable (1-5 minute) automatic detector alarm confirmation in dwelling zones.
Local sounder operates while detector alarm is confirmed.
Full alarm when detector alarm confirmed.
Immediate full alarm when fire detected in communal areas.
Multipoint detector offers 7 modes of detection .
Built-in sounder with 92dBA output.
All devices have built-in EOL monitoring.
Callpoint identification.
EN54 compliant.
Eliminates disruption of nuisance alarms.
Perfect solution for BS5839 pt 6 (HMO's).
No need for mixed systems.



4 Zone Twinflex PLUS panel

4 Zone Twinflex PLUS panel

Ref: TP4


Price: £559.80 (Including VAT at 20%)

Quantity:

As TP2 above

8 Zone Twinflex PLUS panel  Metal Box

8 Zone Twinflex PLUS panel Metal Box

Ref: TP8


Price: £819.00 (Including VAT at 20%)

Quantity:

As TP2 above


Fire & Safety |  Fire Alarm Parts |  Fike Twinflex Panels & Kits

Copyright © 2011

spacer
spacer